家家通 | 所有行业 | 所有企业                                          加入家家通,生意很轻松! ·免费注册 ·登陆家家通 ·设为首页
关于我们
关于我们
今日加盟
今日加盟
会员中心
会员中心
 
当前位置: 首页 » 供应产品 » 食品机械/饮料机械/食品饮料 » 五花八门 »特别德国原装VIBRA振动机系列

特别德国原装VIBRA振动机系列

<%=cpname%>
产品价格: 7/人民币 
最后更新: 2016-01-05 09:47:25
产品产地: 6
发货地: 2 (发货期:当天内发货)
供应数量: 不限
有效期: 长期有效
最少起订: 1
浏览次数: 55
询价  试用会员产品
  • 公司基本资料信息
    • 北京康拉德科技有限公司
    • 张敏小姐 经理
    • 会员[试用会员产品]
    • 邮件15321344403@163.com
    • 手机15321344403
    • 电话
    • 传真
    • 地址北京市朝阳区定福庄北里东领鉴筑3号楼5层7号
    • 进入商铺
     
    产品详细说明

    德国REMO-HSE原装进口高压开关
            德国REMO-HSE原装进口高压开关

         德国Zollern原装轴承系列
            德国Zollern原装轴承系列

        特别德国原装VIBRA振动机系列
            特别德国原装VIBRA振动机系列

    ? Quick Start Guide/
    Instruction Manual
    Easy-to-read information and graphical presentation
    ? High-resolution backlit graphics display
    ? Up to 3 measuring parameters at a glance
    ? Clear presentation of measurement, units, individual
    text and assigned relays and current interfaces
    ? Daily or weekly trend
    curves for individual or
    several parameters in a
    single graph
    ? Status line for auxiliary
    information
    User Interface
    Auto Functions of All Modules
    AutoClean ? An innovative method for automatic self-cleaning whose high efficiency allows measurements
    in slightly polluted wastewater, e.g. in sewage treatment plant effluent, without sample preparation.
    AutoCal Automatic calibration and plausibility check at predefined time intervals – resulting in a higher degree of accuracy.
    AutoKorr A correction algorithm developed by WTW for compensating background color
    in the sample in photometric measuring methods.
    AutoFlow Function for continuously monitoring the container filling levels and the sample/reagent flow in the module and
    for producing useful maintenance messages.
    AutoTherm Automatic temperature control means that ambient temperature influences on the analytical results can be disregarded.
    Intervall Software function for regular measurements at selectable intervals.
    Intervall-Program Measuring program – for a period of one week the measuring intervals within two-hour sections can be defined. This
    allows extremely reagent-saving operation in periods where experience has shown that only slight variations in the
    measurements are to be expected.
    System Inputs & Outputs
    TresCon ? standard features include a number of analog and digital outputs, which provide enhanced data management
    and control capabilities of the system. All inputs and outputs can be assigned at will to the installed analyzer modules and
    freely configured.
    Serial Interfaces
    Two serial input/output interfaces which can be operated
    independently are standard equipment in the analyzer.
    While the RS 232, for example, is linked to a local device
    for data recording – such as a printer –, the RS 485 inter-
    face allows for remote control of the unit.
    If a telephone connection is available then TresCon ? can be
    accessed and controlled by a remote computer via the
    RS 232 interface and a modem. The RS 485 interface also
    allows TresCon ? to be coupled to PROFIBUS-DP by using a
    gateway.
    PID Control
    As an alternative to outputting the measured values, the
    analog outputs of TresCon ? can also be used as PID con-
    trollers for control and feedback control purposes.
    Proportional Control (PW/PF)
    As well as being used for report or limit contacts, each relay
    can also be pro grammed as an impulse or frequency con-
    troller. Depending on the control function, in I/F control
    either the impulse length (I-control) or the impulse fre-
    quency (F-control) of the output signal is varied.
    Inlet Aeration
    Inlet Aeration
    Final Effluent
    Accessories Samplers Sample
    Preparation
    Analyzer Monitors IQ S enSor n et General Descrtption
    of Meters
    For information visit www.WTW.com for a customer care center near you
    109
    TresCon ?
    TC/PU 1 Two-Channel Permeate Switcher
    By means of the TC/PU 1 Two-Channel Permeate Switcher
    TresCon ? can analyze samples from two different sampling
    locations in sequence. As the two analyzer samples, e.g. the
    permeate flows from two PurCon ? systems, are directly in
    contact with the switching valve, any alteration in concen-
    tration of either of the permeate flows can be registered
    within minutes. Up to three TresCon ? modules can be con-
    nected to the TC/ PU 1 Two-Channel Permeate Switcher. It
    is available as an accessory and can be mounted on the
    side of the TresCon ? stand in a space-saving manner.
    Control is via the TresCon ? terminal. The mA outputs and
    relays can be parametrized accordingly so that no addi-
    tional external reporting units are necessary.
    Technical Data TresCon ?
    Sample preparation TresCon ? analyzer modules require continuous sample input with a low solids content;
    typical sample preparation with PurCon ? (see Sample Preparation Section).
    Sample delivery Sample presented for analysis in overflow vessels supplied; up to three analyzer modules can be connected to one
    overflow vessel. Operation with up to three overflow vessels is also possible (parallel analysis of different samples).
    Interfaces 3 freely configurable galvanically separated 0/4 - 20 mA outputs, 12 potential-free relays, freely configurable, RS 232, RS 485.
    Electronical connections 230 VAC ± 10%, 50 Hz / 115 VAC ± 10%, 50 – 60 Hz
    Ambient conditions Storage temperature – 77 … 140 °F (– 25 … 60 °C), operating temperature 32 … 104 °F (0 … 40 °C),
    climate class 4, VDI/VDE 3540 Bl. 2
    Test marks CE, DIN-GOST
    Instrument protection Safety class I according to IEC 1010-1/EN 61010-1
    Weight Empty housing: 59.5 lb (27 kg); each module: 22 lb (10 kg); mounting column: 55 lb (25 kg)
    Guaranty 2 years for defects of quality
    The technical data of the analyzer modules
    can be found on pages 50 to 69.
    IP 54
    Ordering Information
    Ein TresCon ? basic instrument
    (without module) consisting of:
    TresCon ? terminal, mounting column, reagent tray, overflow vessels
    for max. three modules, terminal operating instructions (German)
    Order No.
    If operating instructions in English are required
    these must be ordered separately.
    TresCon ? basic instrument (with first analyzer module)
    1 st Module
    2 nd Module
    3 rd Module
    TresCon ? Ammonia, A111 Basic instrument with ON 110 module for Ammonium-Nitrogen 8A-1 3
    TresCon ? Nitrate, N211 Basic instrument with ON 210 module for Nitrite-Nitrogen 8A-2 3
    TresCon ? Nitrite, N511  Basic instrument with ON 510 module for Nitrite-Nitrogen 8A-3 3
    TresCon ? Orthophosphate, P211/MB 1 Basic instrument with OP 210/MB1 module for Orthophosphate (measuring range 1) 8A-4 3
    TresCon ? Orthophosphate, P211/MB 2 Basic instrument with OP 210/MB2 module for Orthophosphate (measuring range 2) 8A-5 3
    TresCon ? Orthophosphate, P211/MB 3 Basic instrument with OP 210/MB3 module for Orthophosphate (measuring range 3) 8A-6 3
    TresCon ? Nitrate/SAC, S211 Basic instrument with OS 210 module for Nitrate-Nitrogen and SAC 8A-7 3
    TresCon ? Total Phosphorus, P511 Basic instrument with OP 510 module for Total Phosphorus (requires two module places) 8A-8 X 3
    Ordering options for additional analyzer modules (2nd/3rd modules)
    Without additional analyzer module 0 0
    NH 4 analyzer module (Ammonia-Nitrogen), OA110 1 1
    NO 3 analyzer module (Nitrate-Nitrogen), ON210 2 2
    NO 2 analyzer module (Nitrite-Nitrogen), ON510 3 3
    PO 4 analyzer module (Orthophosphate), OP 210/MB1 4 4
    PO 4 analyzer module (Orthophosphate), OP 210/MB2 5 5
    PO 4 analyzer module (Orthophosphate), OP 210/MB3 6 6
    NO 3 /SAC analyzer module (Nitrate-Nitrogen and SAC), OS 210 7 7
    Other ordering options
    Without feet (wall mounting with mounting stand) 0
    With feet (free-standing arrangement) 1
    Please complete the ordering number by entering the required versions: 3
    Ordering example: TresCon ? Ammonium A111 with additional nitrate module,
    for wall mounting with mounting stand
    8A-1 2 0 3 0
    2
    Year
    Guaranty
    For information visit www.WTW.com for a customer care center near you
    110
    TresCon ? Uno
    ? Compact dimensions
    ? Economical
    ? Easy to Use
    Online-Analysis – reliable · compact · economical
    The new TresCon ? Uno uses a single channel version of our
    popular multi channel TresCon ? Analyzer.
    The TresCon ? Uno instruments are designed for control and
    monitoring at waste water treatment plants. The compact
    size of TresCon ? Uno at a reasonable price offers to the user
    a good price-performance-ratio for the measurement of
    nutrient parameters.
    System Descrtption:
    TresCon ? Uno consits of a basic unit  1 , an analyzer-
    module  2 , and a reagent tray  3 . System can be wall
    mounted.
    Operation safe and Service friendly:
    Many automatic diagnosis functions help the user with
    operation and maintenance. The modular design allows for
    the quick and easy exchange or replacement of modules.
    Maintenance and Service
    TresCon ? systems are service-friendly requiring little or no
    maintenance. The numerous useful system functions are
    easily accessed and changed. The operator is also prompted
    as to service intervals automatically. It has also been
    designed for easy access and maintenance.
    1
    2
    3
    Accessories Samplers Sample
    Preparation
    Analyzer Monitors IQ S enSor n et General Descrtption
    of Meters
    For information visit www.WTW.com for a customer care center near you
    111
    TresCon ? Uno
    Technical Data TresCon ? Uno
    TresCon ? Uno
    Measuring ranges
    Detailed technical data:
    see TresCon ? modules in parameter
    section*
    Ammonium:  0.05 … 1000 mg/l NH 4 -N
    Nitrate:  0.10 … 60 mg/l NO 3 -N
    Nitrite:  0.05 … 1,200 mg/l NO 2 -N
    Orthophosphate Range 1:  0.05 … 3,00 mg/l PO 4 -P
    Orthophosphate Range 2:  0.10 … 10,0 mg/l PO 4 -P
    Orthophosphate Range 3:  0.10 … 25,0 mg/l PO 4 -P
    Nitrate/SAC:  0.10 … 60 mg/l NO 3 -N / 0.10 … 200 m -1
    *See also OA 110,  page 50
    *See also ON 210,  page 55
    *See also ON 510,  page 56
    *See also OP 210,  page 68
    *See also OP 210,  page 68
    *See also OP 210,  page 68
    *See also OS 210,  page 55
    Calibration Automatic 2-point-calibration (works calibration for N211 and S211)
    Measurement intervals Cont., 5, 10, 15, 20, 25, 30 min to be set depending on the parameter
    Sample preparation Depending on the application: none, PurCon ? or PurCon ? IS
    Mains 230 VAC ± 10 %; 50 Hz / 115 VAC ± 10 %; 50/60 Hz
    Operation temperature 32 … 104 °F (0 … 40 °C)
    Dimensions, Weight
    (W x H x D, lb/kg)
    Analyzer: 24.1 x 30.5 x 13 in. (612 x 775 x 329 mm), approx. 77.2 lb/35 kg
    Reagent tray: 23.2 x 2 x 14.2 in. (590 x 50 x 360 mm), approx. 37.5 lb/17 kg
    Guaranty 2 years for defects of quality
    Ordering Information
    TresCon ? Uno Order No.
    TCU/A111 TresCon ? Uno – Ammonium  NH 4 -N 820 101
    TCU/N211 TresCon ? Uno – Nitrate  NO 3 -N 820 102
    TCU/N511 TresCon ? Uno – Nitrite NO 2 -N 820 103
    TCU/P211-MB1 TresCon ? Uno – Orthophosphate Range 1  PO 4 -P/MB1 820 104
    TCU/P211-MB2 TresCon ? Uno – Orthophosphate Range 2  PO 4 -P/MB2 820 105
    TCU/P211-MB3 TresCon ? Uno – Orthophosphate Range 3  PO 4 -P/MB3 820 106
    TCU/S211 TresCon ? Uno – Nitrate/SAC  NO 3 -N / SAC 820 107
    The Instruments include:
    ? big graphical display
    ? three 0/4 - 20 mA outputs
    ? 12 relay interfaces
    ? RS 232 interfaces
    ? RS 485 interfaces
    ? different controller functions
    (PID, pulse-width, frequency)
    Connection to PROFIBUS-DP via Protocol Converter
    IP 54
    2
    Year
    Guaranty
    EcoLine/QuadroLine ?
    PROFIBUS-DP
    interface
    RS-485
    interface
    PKV 30-DPS
    PROFIBUS-DP
    + 24V
    PKV
    30-
    DPS
    TresCon ?
    TresCon ? Uno
    For information visit www.WTW.com for a customer care center near you
    Sample Preparation
    On-Line Sample Preparation –
    Continuous · Reliable · Low Maintenance
    Sample preparation is usually necessary for the reliable operation of on-line analyzers in municipal and industrial wastewa-
    ter treatment facilities. Preparing the sample prevents solids and bacteria from contaminating the analysis system and its
    com po nents. The sample preparation system and the analysis system must be matched to each other so that accurate and
    continuous measuring operation can be guaranteed together with low maintenance requirements.
    In combination with a suitable sample preparation system, WTW analysis systems provide greater operating reliability and
    availability.
    WTW Sample Preparation Systems
    ? Biological Treatment
    For the most frequent application of on-line analyzers, their
    use in the biological treatment of wastewater treatment
    plants, WTW has developed the PurCon ? sample prepara-
    tion system. In contrast to preparation techniques based on
    the sedimentation principle, this low-maintenance system
    provides a constant flow of permeate.
    ? Final Effluent
    For monitoring final effluent, WTW TresCon ? Analyzers
    require no sample preparation. The TresCon ? ’s
    AutoClean ? feature allows the treated sample to be
    measured directly.
    The new P 700 IQ orthophosphate analyzer requires a special sample preparation,
    which is only offered for this analyzer. For further information see page 67.
    112
    Accessories Samplers Sample
    Preparation
    Analyzer Monitors IQ S enSor n et General Descrtption
    of Meters
    For information visit www.WTW.com for a customer care center near you
    PurCon ?
    ? Continuous sample preparation
    ? Solid-free and bacteria-free permeate
    ? BubbleClean ? , self-cleaning feature –
    Low Maintenance
    PurCon ? – the perfect sample preparation
    PurCon ? is a continuously operating sample preparation
    system which has been specially designed for use in wastewater
    treatment facilities. In contrast to conventional preparation
    systems, e.g. by sedimen tation, the PurCon ? unit provides a
    continuous flow of solid-free and bacteria-free perme ate;
    BubbleClean ? feature results in low maintenance requirements.
    This sample preparation system is suitable for a wide range of
    applications in the wastewater treatment plants; even for
    applications in the biological treatment with difficult-to-sedi-
    ment sludge components.
    The PurCon ? sample preparation system is the ideal
    complement to the TresCon ? analysis system as up to three
    on-line analysis modules can be supplied with permeate
    simultaneously.
    In typical applications in municipal waste water treatment
    plants, e.g. in the biological tank (3 – 6 g/l sludge), 6 months
    maintenance-free operation is possible.
    System descrtption
    The PurCon ? sample preparation system consists of a sample
    preparation unit and a control unit with peristaltic pump for
    permeate delivery. The unit is fully mounted and is built into a
    V4A stainless steel housing with a door in the front panel.
    To supply the raw water to the PurCon ? system a
    submersible pump is required; its type and size depend
    upon the local conditions. Sample discharge is pressureless
    (outlet diameter > 1.97 in./50 mm).
    Technical Data PurCon ?
    Permeate  Feed to Analyzer  Continuous
    Yield 3.6 l/h max., adjustable in four increments
    Quality Free of solid matter and bacteria
    Sample Delivery Minimum … maximum 400 … 1.500 l/h approx.
    Connections Sample inlet Hose barb fitting, 3/4“ I.D.
    Drain outlet  PVC pipe fitting, 51.97 in. (50 mm) I.D., pressureless
    Rinsing outlet Hose barb fitting, 3/4“ I.D.
    Permeate outlet  Screw fitting, 0.06“ dia. (1.54 mm)
    Electrical
    Requirements
    Voltage 230 VAC / 115 VAC (depending on version)
    Power consumption 150 VA approx. (without pump)
    EMC  According to EN 62 326 class B, Annex A, FCC class A
    Mechanical,
    Protection Rating
    Dimensions (HxWxD) 2.38 x 1.86 x 0.71 ft. (735 x 575 x 220 mm)
    Material 316 stainless steel; IP 33
    Weight Approx. 79.38 lb (36 kg)
    Maintenance Requirements Municipal applications Depends on location and wastewater load, typically 20 min / month
    Ambient Conditions Temperature Storage: – 13 … 140 °F (– 25 … 60 °C) / Operating: 32 … 104 °F (0 … 40 °C)
    Certification CE, TüV-Mark, DIN-GOST
    Guaranty 2 years for defects of quality
    Ordering Information
    PurCon ? Order No.
    PurCon ? / 230 Sample preparation system for 230 VAC, with 1 m permeate tubing with adapter, 3 hose clamps for feed tubing  810 000
    PurCon ? / 115 Sample preparation system for 115 VAC, with 1 m permeate tubing with adapter, 3 hose clamps for feed tubing 810 008
    2
    Year
    Guaranty
    Biological Treatment
    PurCon ?
    113
    For information visit www.WTW.com for a customer care center near you
    PurCon ? IS
    ? Direct in-situ operation
    ? Continuous sample preparation
    ? Self-cleaning “BubbleClean ? ”
    Sample Preparation on-site
    with no external Pumps required
    PurCon ? IS consists of a filter unit 1, that is put directly in
    the sample, a suction hose 2, a control unit for outside
    mounting 3, that takes the permeate in and a permeate
    line 4 for the transport of the permeate to the analyzer
    units. The permeate line can – according to the ambient
    temperature conditions at the site – be specified with or
    without freeze protection.
    At the end of the permeate line a box 5, is mounted that
    delivers the permeate.
    Technical Data PurCon ? IS
    Permeate Stream Sufficient for PurCon ? IS/2-230: supply of one TresCon ? analyzer module
    PurCon ? IS/4-230: supply of up to three TresCon ? analyzer modules
    Hose Length Suction hose: 5.47 yds (5 m)
    Permeate line 5.47, 10.94 or 21.87 yds (5, 10 or 20 m)
    Operating Temperature  – 4 … 104 °F (– 20 … + 40 °C); with freeze protection
    Applications Suited for outside operation
    Mounting Filter unit: Chain-, railing-, wall-, basin-, column mounting
    Control unit:  railing-, wall mounting
    In combination with mounting sets and the WTW mounting system
    Dimensions (B x H x T, lb/kg),
    Weight, Protection Rating
    Filter unit: 1.04 x 3.03 x 0.23 ft. (321 x 934 x 71 mm), 22 lb (10 kg), IP 68
    Control unit:  1.34 x 1.66 x 1.12 ft. (412 x 513 x 345 mm), 33 lb (15 kg), IP 33
    Guaranty 2 years for defects of quality
    Further Accessories see brochure “Product Details”
    Ordering Information
    PurCon ? IS Order No.
    PurCon ? IS/2-230 PurCon ? IS filter unit with 2 filter membranes, 5.47 yds (5 m) suction hose and control unit
    (230 V AC) for supply of one TresCon ? analyzer module
    810 050
    PurCon ? IS/4-230 PurCon ? IS filter unit with 4 filter membranes, 5.47 yds (5 m) suction hose and control unit
    (230 V AC) for supply of up to three TresCon ? analyzer modules
    810 051
    PCIS-Set115 Adaption set to 115 V AC mains supply 810 070
    Permeate line – required for operation Order No.
    PCIS-PL5/H 5.47 yds (5 m), with freeze protection 810 065
    PCIS-PL10/H 10.94 yds (10 m), with freeze protection 810 066
    PCIS-PL20/H 21.87 yds (20 m), with freeze protection 810 067
    PCIS-MSK Set for chain mounting for PurCon ? IS filter unit  810 071
    PCIS-MSS Set for bar mounting for PurCon ? IS filter unit  810 072
    PCIS-MSG Set for bar mounting for PurCon ? IS control unit  810 073
    2
    Year
    Guaranty
    1
    2
    3
    5
    4
    114
    Accessories Samplers Sample
    Preparation
    Analyzer Monitors IQ S enSor n et General Descrtption
    of Meters
    For information visit www.WTW.com for a customer care center near you
    Final Effluent
    Secondary Sedimentation
    Technical Data PF 105
    Tubing connections 20 mm dia.
    Permeate tubing Length 1.09 yds (1 m), 0.24 in. (6 mm) I.D.
    Feed 1000 … 1500 l/h
    Branch Approx. 3 l/h
    Dimensions ( H x W) 1.28 x 1.07 ft. (395 x 330 mm)
    Pumps are not included in scope of delivery.
    Pumps and further Accessories see brochure “Product Details”
    Ordering Information
    Accessories Order No.
    PF 105 Submersible pump without cutting blade for PurCon ? , PF 105 or FPB 000 670
    VB 105 Low power submersible pump without cutting blade, power 350 W 830 860
    Secondary Sedimentation Stage /
    Final Effluent
    In the effluent water from the secondary sedimentation the concentration of solids is often so high that sample preparation
    is required before on-line analysis can take place. In the effluent from wastewater treatment plant it is possible to carry out
    on-line analysis with TresCon ? without any sample preparation as the analyzer module uses the AutoClean ? method; this is
    a very efficient automatic self-cleaning system.
    If TresCon ? analyzers are used in slightly loaded wastewater
    such as wastewater treatment plant effluent the
    ? PF 105 sample bypass is used to provide the analyzer
    module with unfiltered sample. The unit consists of a
    Y-shaped pipe branch with a valve for regulating the
    flow in the bypass. The supply to the TresCon ? analyzer
    can be set with a second fine valve in the sample
    branch. To protect the TresCon ? analyzer module coarse
    particles are retained by a woven-wire sieve in the
    branch.
    ? Overflow vessel VB 105 with continuous sample flow is
    used to feed the analysis modules with non-filtrated
    sample. The unit is made up of a cylindrical vessel with
    a volume of approx. 2 l. This vessel is continuously
    being flown through and thus always supplys up-to-
    date sample.
    PurCon ?
    Apart from its use in aeration basins, the PurCon ? system is ideal for the preparation of samples from the secondary sedi-
    men tation stage. In such cases PurCon ? also continuously supplies an adequate amount of high-quality permeate. As only
    residual solids need to be removed from the sample, extremely low maintenance requirements are achieved.
    Vorlagebeh?lter
    VB 105
    830860
    Ser.-Nr.: ........
    320 mm
    600 mm
    ? 40 mm
    ? 125 mm
    outflow
    unpressurized outflow
    inlet
    500...1000 l/h
    sediment drain
    DN 20
    DN 20
    PurCon ? IS / Accessories
    PF 105 sample bypass
    Overflow vessel VB 105
    115
    For information visit www.WTW.com for a customer care center near you
    Sampling
    Stationary · Portable
    Sampling is an important factor for the compliance with required regulations and efficient operation. It forms the basis for
    continuous monitoring of quality objectives and criteria, in particular for performance analysis of wastewater treatment
    plants. In addition, sampling systems are used increasingly for managing and optimizing complex production and recycling
    processes. In this context sampling represents the first link in the chain of work procedures for the examination and analy-
    sis of chemical, physical and biological parameters. It thus has a decisive, subsequently irrectifiable, influence on results
    gained from chemical analysis.
    Absolutely reliable provision of representative samples is extremely important, as they provide reliable and consistent
    assessment of contents and water properties.
    Sampling
    ? Sewage Treatment
    ? Municipal Sewerage Systems
    ? Water Protection Control
    The factors directly connected with sampling (sampling
    method, sampling location, sampling storage, sampling
    transport, sampling preservation and the method of
    analysis itself) have another important influential effect
    on the result. Consistent and exacting sampling is
    becoming increasing significant due to the increase of
    required regulations.
    116
    For information visit www.WTW.com for a customer care center near you
    Accessories Samplers Sample
    Preparation
    Analyzer Monitors IQ S enSor n et General Descrtption
    of Meters
    Sampling
    WTW has added two new units for precise sampling with
    the PB 8 and the PB 150-SE12 / -SE24. The PB 8 is a
    compact unit for plant monitoring. PB 150-SE12 / -SE24
    is an automatic, self-emptying instrument for process
    monitoring.
    Functionality
    Sampling devices work according to the proven vacuum or
    peristaltic pump principle used in wastewater engineering.
    The vacuum dosing technology is particularly suitable for
    continuous stationary sample extraction. As sampling is per-
    formed only by means of vacuum or pressure, even heavily
    polluted wastewater with abrasive contents can be
    extracted safely and without wear.
    In contrast, peristaltic pump technology is particularly suit-
    able for short-term mobile sampling at different measuring
    locations.
    Sampling procedure
    Sampling is performed by non-pressurized extraction of
    either a single sample, a qualified sample, a 24 h composite
    sample or a 2 h composite sample from a lower level, e.g.
    from a basin, open channel or pipe under the following
    conditions:
    Time
    Constant sample volume, constant sampling frequency
    Amount
    Constant sample volume, sampling frequency variable
    according to
    throughput volume (0/4 - 20 mA or flow impulse)
    Flow
    Sample volume variable according to throughput volume
    (0/4 - 20 mA or flow impulse), constant sampling frequency
    Event
    Constant sample volume, constant sampling frequency,
    Constant sample filling time or individual samples per bottle
    Combination mode
    Optional combination of time, amount and event sampling
    operation
    117
    For information visit www.WTW.com for a customer care center near you
    2
    Year
    Guaranty
    Technical Data Samplers
    Sampling
    Mains operated
    PB 8 PB 150-2 PB 150-SE
    Applications/
    Specific Features
    Simple robust device for plant
    monitoring in water and wastewater
    Wall / Control panel mounting
    Proven system for process and
    wastewater engineering, even for
    larger polluting load; Frame mounting
    System for continuous, unmanned,
    “around the clock” monitoring.
    For process and water monitoring
    measuring networks. Self-emptying;
    Frame mounting
    Installation Site
    Permanent measuring place
    outdoor installation
    — ● ●
    Frost-free roofed installation ● — —
    Sample Storage
    Thermostatic control /
    cooling heating
    — ● ●
    Passive cooling (IsoBox) Option — —
    Sampling Method
    Vacuum system ● ● ●
    Vacuum system Var — Option Option
    Self-emptying — — ●
    Sampling Method
    Time ● ● ●
    Amount ● ● ●
    Flow volume — Option Option
    Event ● ● ●
    Combination mode ● ● ●
    Communication
    Modem/GSM — Option Option
    RS 232 — ● ●
    System message display — ● ●
    System messages /
    signal outputs
    — Option Option
    Sample Fractioning/Composite Sample
    Storage tanks 25 l ● ● —
    Storage tanks 50 l ● ● —
    12 x 1.1 l IsoBox — —
    2 x 10 l, 4 x 6 l — ● —
    4 x 14 l, 4 x 10 l — ● —
    12 x 2.9 l — ● —
    12 x 2 l glass — ● 12 x 1,6 l glass
    24 x 1 l — ● —
    24 x 1 l glass — ● —
    24 x 2 l glass — — Option
    Guaranty 2 years for defects
    of quality
    2 years for defects
    of quality
    2 years for defects
    of quality
    118
    For information visit www.WTW.com for a customer care center near you
    Accessories Samplers Sample
    Preparation
    Analyzer Monitors IQ S enSor n et General Descrtption
    of Meters
    Sampling
    Samplers for use in hazardous areas on request.
    Sampling
    Mobile Operation
    PB 25 S / PB 25 S/24 PB 13 PB 17
    Applications/
    Specific Features
    Compact design for mobile water
    and wastewater plant monitoring
    Modular system for mobile process
    and wastewater engineering tasks,
    even for large polluting load
    Compact system with large
    sample capacity for examination series
    and load determination in the field
    Installation Site
    Frost-free roofed installation ● ● ●
    Power consumption
    Battery ● ● ● pluggable
    Power supply/recharger external / buffer operation external / buffer operation external / buffer operation
    Sample Storage
    Passive cooling
    (cooling accu.)
    — IsoBox ●
    Sampling System
    Vacuum system — ● ●
    Peristaltic pump system ● — —
    Sampling Method
    Time proportional ● ● ●
    Amount proportional ● ● ●
    Flow volume proportional ● — —
    Event proportional ● ● ●
    Combination mode ● ● ●
    Communication
    Modem/GSM — Option Option
    RS 232 Option ● ●
    System message display ● ● ●
    Sample Fractioning/Composite Sample
    Storage tanks 10 l PE Option ● Option
    Storage tanks 13 l PE — — —
    Storage tanks 25 l PE ● (26 l) — —
    2 x 5 l PE — — —
    12 x 0.5 l glass Option — —
    12 x 1,1 l PE Option — —
    12 x 1 l glass — — —
    24 x 1 l PE Option Option ●
    Guaranty 2 years for defects
    of quality
    2 years for defects
    of quality
    2 years for defects
    of quality
    119
    For information visit www.WTW.com for a customer care center near you
    The instruments of the PB 150-2 series with their numerous
    versions are stationary samplers for permanent outdoor use
    under rough ambient conditions. The instruments are equipped
    with low maintenance and self-cleaning vacuum technology
    which has been field-tested and proven over years in the
    wastewater engineering sector. The devices are a further
    develop ment of the PB 150 series and offer even more power-
    ful and more economical sample storage with complete
    stainless steel fitting and a technically optimized temperature
    control system with a forced-ventilation liquifier. With its
    independent operation from the control system, the multiple
    point regulation system for cooling and heating the sample
    storage unit offers safe temperature control, even when the
    control system is turned off. In the light of representative
    samples for subsequent analysis combined with water content
    assessment, thermostatic control plays an important role.
    With its overall maintenance- and service-friendly equipment
    configuration with separate energy, control and wet area and
    its variable control system with memory for user programs,
    the device offers a high degree of efficiency and availability.
    The “Var” version with a variable dosing container is available
    for users who wish to combine flow proportional sampling
    with the advantages of vacuum technology. This patented
    version guarantees a reproducible sampling volume which
    corresponds to the individual flow volume (0/4 - 20 mA)
    and permits digital sampling volume adjustment.
    Sampling can be traced using the display or fully documented
    and programmed using the communication software which
    is linked to a PC by an interface.
    PB 8
    PB 150-2
    ? Vacuum system
    ? Continuous adjustment of sample
    volume
    ? Optional signal output for IsoBox /
    distributor
    ? Vacuum system for operational
    safety, low maintenance
    ? Sampling traceability through data
    memory and interface mode
    ? Optional flow proportional Var unit
    Sampler PB 8 for plant monitoring
    Device system equipped with vacuum technology for frost-
    free roofed installation with mains supply. This robust and
    compact instrument contains proven components and is
    easy to operate. Controls were reduced to an absolute min-
    imum. The operator guidance is menu driven showing all
    relevant parameters in the display. Thus providing a system
    which is fully sufficient for a multitude of tasks at a very
    favorable price-performance ratio. The addition of the
    IsoBox and cable connection accessory components pro-
    vides the user with an inexpensive version for 2 h compos-
    ite samples. With this powerful and reliable device, the
    operator has a low cost sampling instrument at his disposal
    which is reduced to core functionalities.
    Stationary Samplers
    120
    For information visit www.WTW.com for a customer care center near you
    Accessories Samplers Sample
    Preparation
    Analyzer Monitors IQ S enSor n et General Descrtption
    of Meters
    Stationary Samplers
    Device alternatives and additional accessories see brochure “Product Details”
    PB 150-SE
    ? Vacuum technology for operational
    safety
    ? Sampling traceability through pro-
    gram memory
    ? System monitoring
    For permanent stationary use in water and wastewater
    monitoring measuring networks, automatically self-empty-
    ing samplers are available from the PB 150-SE 12 series
    equipped with 12 or PB 150-SE 24 equipped with 24 sam-
    ple vessels. These devices operate with proven low mainte-
    nance and self-cleaning vacuum technology. The sample
    vessels are available in glass (Duran 50) and are easily
    extractable for cleaning. The bottle is sealed and emptied
    by means of robust constriction hose valves. The fractioned
    sample in the device is automatically discarded (emptied)
    or manually extracted for analysis. Immediately after empty-
    ing a sample which is no longer required, the relevant bot-
    tle is rinsed with pressurized clean water before it is refilled.
    These devices can store up to 12/24 reserve samples with-
    out supervision. In case of serious disruption of operation or
    other events, event samples can be taken. The PB 150-SE
    devices are thus not only suitable for “around the clock
    sampling” for routine monitoring tasks, but also for event
    sampling or for a combination of both. Sampling is trace-
    able by means of the program and error memory readout
    on the display or can be documented and programmed
    from a PC using the communication software.
    Ordering Informations Stationary Samplers
    Stationary Samplers Order No.
    PB 8-230 V Compact sampler 230 V / 50 / 60 Hz for wall mounting 000 180
    PB 8-115 V Compact sampler 115 V / 50 / 60 Hz for wall mounting 000 181
    PB 150-2/1 Sampler with thermostatic control for outdoor installation (25 l storage container), 230 V 50 / 60 Hz 000 190
    PB 150-2/R12 Sampler with thermostatic control for outdoor installation (12 x 2.9 l), 230 V 50 / 60 Hz 000 191
    PB 150-SE/12 Sampler, self-emptying, with 12 glass bottles (12 x 1.6 l), 230 V 50 / 60 Hz 000 188
    PB 150-SE/24 Sampler, self-emptying, with 24 glass bottles (24 x 2 l), 230 V 50 / 60 Hz 000 193
    2
    Year
    Guaranty
    121
    For information visit www.WTW.com for a customer care center near you
    PB 13
    PB 17
    ? Low maintenance vacuum system
    ? Large number of sample cycles with
    just one battery charge
    ? Sampling is traceable on display
    ? Energy saving vacuum technology
    ? Very compact build
    ? Large bottle capacity
    Portable sampler PB 13 with vacuum technology for universal
    applications. Thanks to its energy saving functionality, a large
    number of sample cycles or comprehensive sampling programs,
    respectively can be performed with just one battery charge.
    PB 13 can be mounted directly on all common storage
    containers or onto the IsoBox, which is available in different
    versions. When combined with IsoBox, it provides the user
    with a practical and modularly extendable system with passive
    cooling. IsoBox is not only suitable for temperature control of
    samples but also for safe protected sample transport.
    The portable sampler PB 17 with vacuum technology and its
    immensely compact build is also suitable for field use in diffi-
    cult terrain. With its large utilizable sample capacity of 24 x 1 l
    segment bottles, it is particularly suitable for extensive moni-
    toring tasks and load determination. The lower part of the
    device has a double-wall insulation and offers full sample
    protection and a passive cooling facility with dry ice or cold
    storage accumulators. The cover, which is equipped with a
    lock, offers protection against the elements and unauthorized
    access. Its easy-to-change rechargeable battery with plug
    connection prevents downtimes caused by battery charging
    and facilitates a high level of availability.
    Portable Samplers
    122
    For information visit www.WTW.com for a customer care center near you
    Accessories Samplers Sample
    Preparation
    Analyzer Monitors IQ S enSor n et General Descrtption
    of Meters
    Portable Samplers
    Additional accessories see brochure “Product Details”
    PB 25 S / PB 25 S/24
    ? Compact
    ? Time, amount, event and flow
    proportional and combined sampling
    ? Precise non-contacting water
    measurement (optional)
    ? Already starting with
    5 ml dosing volume
    Portable sampler PB 25 S with peristaltic-pump dosing system
    and integrated rechargeable battery for collected samples
    26 l as well as fractioned samples via turnable distributor on
    12 x 1 l, 24 x 0.5 l or 24 x 1 l sample containers. Thanks to
    the linked non-contacting water recognition (optional) also
    waters with considerably low or high conductivity can be
    precisely sampled.
    Ordering Information Portable Samplers
    PB 13 Order No.
    PB 13 Portable microprocessor-controlled liquid sampler with vacuum dosing system and built-in
    rechargeable battery. Delivery includes 5 m suction tubing, screw fitting and tubing end piece.
    Not included: battery charger, sample containers or IsoBox.
    The required accessories for PB 13 must be ordered separately.
    000 184
    PB 17 Order No.
    PB 17 Portable microprocessor-controlled liquid sampler in plastic housing with vacuum dosing system and
    built-in rechargeable battery.
    Delivery includes 5 m suction tubing, screw fitting, tubing end piece and 24 x 1 l PE sample bottles.
    Not included: battery charger. The required accessories for PB 17 must be ordered separately
    000 186
    PB 25 S and PB 25 S/24 Order No.
    PB 25 S Portable sampler with peristaltic pump dosing system, built-in rechargeable battery and battery
    charger as well as turntable distributor for 12 sample vessels.
    Supplied with 2 x 2 m suction tubing with quick-release coupling, suction piece and wastewater cap.
    Not included: sample containers
    (must be ordered separately, for 12 x 0.5 l glass bottles insert EW/25/0.5 is also required)
    000 103
    PB 25 S/24 Portable sampler with peristaltic pump dosing system, built-in rechargeable battery and battery
    charger as well as turntable distributor for 24 sample vessels.
    Supplied with 2 x 2 m suction tubing with quick-release coupling, suction piece and wastewater cap.
    Not included: sample containers (must be ordered separately)
    000 105
    2
    Year
    Guaranty
    123
    For information visit www.WTW.com for a customer care center near you
    Accessories
    Practical and Functional Components
    For optimal configuration of the moni to ring station, the instruments are supple men ted by an extensive range of mechani-
    cal installation and assembly aids and useful accessories. These functional and practical tools provide the user with tailor-
    made and well thought -out solutions for almost every applica tion.
    All mechanical system components are manufactured from corrosion resistant materials. They are easy to assemble and
    completely maintenance free. The modular concept and the large design variety facilitate trouble-free adaption to the spe-
    cific appli cation requirements and installation circumstances.
    Accessory scheme
    ? Junction boxes
    ? Sensor extension assemblies
    ? Mounting hardware
    ? Flow-thru adapters
    ? Valve Assemblies
    ? Cleaning Systems
    124
    150 mm 163 mm
    ? 185 mm
    For information visit www.WTW.com for a customer care center near you
    Accessories Samplers Sample
    Preparation
    Analyzer Monitors IQ S enSor n et General Descrtption
    of Meters
    ?40 mm
    UA x
    ? 1.57 in.
    (40 mm)
    Sensor
    UA x
    ? 1.57 in.
    (40 mm)
    52.99 in. (1346 mm)
    42.01 in. (1067 mm)
    51.3 in. (1303 mm)
    48.8 in. (1239.5 mm)
    23.46 in. (596 mm)
    12.48 in.
    (317 mm)
    19.27 in. (489.5 mm)
    21.77 in. (553 mm)
    ? 1.57 in.
    (40 mm)
    Junction Boxes and Holders
    Junction Boxes
    Analog
    Sensor extensions
    Analog & Digital
    Sensor holders
    Analog & Digital
    KI/S KI/pH 170
    UA 55
    EH/U 170
    UA 130
    EH2/U 170
    UA-SO
    EH3/U 170
    This passive junction box is used for extension cabling
    between WTW sensors and the EcoLine and QuadroLine ?
    series monitors.
    Junction box with integrated impedance converter is
    designed to connect high impedance pH electrodes to
    WTW pH monitors over relatively long distances of up to
    330 ft (100 m).
    Armored length without sensor 12.48 in. (317 mm).
    Single sensor holder
    Armored length without sensor 42.01 in. (1067 mm).
    Twin sensor holder
    Armored length without sensor:
    stepless selectable between 9.45 and 102.36 in.
    (240 - 2600 mm).
    Triple sensor holder
    Order No.: 108 606
    Order No.: 109 260
    Order No.: 109 320
    Order No.: 109 261
    Order No.: 109 323
    Order No.: 109 263V
    Order No.: 109 325
    Order No.: 108 596
    The universal extension assemblies made of PVC are used for mounting and mechanically protecting all 650, 690, 70X and
    70X IQ series WTW sensors. The extension assemblies are available with two different standard lengths of armor; special
    armor lengths can be defined in your order. The assemblies are supplied with a stainless steel handle and a set of seals.
    UA 55
    Equipped with oxygen
    sensor TriOxmatic ? 700
    Equipped with oxygen
    sensor TriOxmatic ? 700
    Sensors not
    included with
    assemblies
    UA 130
    Equipped with oxygen
    sensor TriOxmatic ? 700
    UA-SO
    EH3/U 170 e.g. with mounted conducti-
    vity cell
    125
    For information visit www.WTW.com for a customer care center near you
    Swing mounting
    assembly
    EH/F 170-1.5
    EH/F 170-2.5
    Extension
    assembly incl.
    handle UA 130
    UA 55
    EH/U 170
    8.11 ft. (2500 mm)
    4.86 ft (1500 mm)
    Series 700/
    690/650
    700 IQ
    Sensors
    Extension
    assembly incl.
    handle UA 130
    UA 55
    6.39 ft (1970 mm)
    2.01 ft
    (620 mm)
    Pendulum assembly
    EH/P 170
    Pendulum rod shown 90° rotated
    Series 700/
    690/650
    700 IQ
    Sensors
    Wall fixture
    EH/W 170
    UA 55
    0.84 ft.
    (260 mm)
    twistable/
    rigid
    Extension
    assembly incl.
    handle UA 130
    Series 700/
    690/650
    700 IQ
    Sensors
    ca. 850
    330
    Mounting Hardware
    Measurements in Basins or in Open Channels
    Wall mounting
    for universal extension assemblies UA 55/ UA 130
    Measurements in very variable water levels
    or in rivers, lakes, etc.
    Sensor Float S 200
    Measurements in Basins
    Recommended sensor holding device:
    Swing mounting assembly
    Measurements in Open Channels
    Recommended sensor holding device:
    Pendulum assembly
    Installation Flexibility
    The WTW mounting hardware constitutes a flexible
    mechanical system in which the individual components are
    optimally matched. With the selection and combination of
    various sensor holders, mounting stands and fastening ele-
    ments, tailor made solutions can be established for the
    appropriate configuration of the measuring stations; as the
    diagrams show.
    Pendulum suspension
    GWA Weight Ring
    Material: PVC
    (polystyrene foam)
    126
    For information visit www.WTW.com for a customer care center near you
    Accessories Samplers Sample
    Preparation
    Analyzer Monitors IQ S enSor n et General Descrtption
    of Meters
    Floor mounting stand,
    long
    BE/ST 170
    5.51 ft. (1700 mm)
    Sun shield
    SSH/IQ
    Monitor
    Swivel fixture
    BE/R 170-D
    Handrail
    system
    Masonary fixture
    BE/M 170
    Mounting stand,
    short
    BE/ST 170-M
    3.15 ft. (970 mm)
    Sun shield
    SSH/IQ
    Monitor
    Sun shield
    SSH/IQ
    Monitor
    Mounting stand,
    short
    BE/ST 170-R
    Pipe rail
    2.01 ft
    (620 mm)
    3.15 ft (970 mm )
    Mounting Hardware
    Mounting Stands and Fixtures
    Floor Mounting Stand Handrail Mounting (swivel-mounted)
    Wall Mounting Pipe Mounting Top-of-Wall Mounting
    Details see page 128/129
    127
    For information visit www.WTW.com for a customer care center near you
    Sensor Holding Devices
    EH/F 170  Order No.: 109 272, 109 273
    The SensoClean swing mounting assembly consists of a 4.86 ft.
    or 8.11 ft. (1.5 or 2.5 m) long boom and a 13 ft. (4 m) long
    plastic chain for height adjustment of the sensor. It may also
    hold sensor extension assemblies. Particularly in turbulent
    flows, the freely swinging suspension produces a self-clean-
    ing effect of the sensor, making the swing mounting espe-
    cially suitable for operation in basins; e.g. in the aeration
    tank of a wastewater treatment plant.
    Boom length 4.86 ft. or 8.11 ft. (1.5 or 2.5 m)
    Material Stainless steel 1.4301
    Chain material Polyethylene
    VIS Set/EH  Order No.: 481 073
    Supplemental kit for horizontal mounting of a UV(-VIS)-
    sensor (NitraVis ? , CarboVis ? , NiCaVis ? ). Suitable for basin
    or channel mounting in combination with swing mounting
    assembly EH/F 170.
    Chain material Polyethylene
    EH/P 170  Order No.: 109 270
    The SensoClean pendulum mounting assembly consists of a
    boom with a pendulum head and an angled pendulum
    rod. It is fitted at the top end with a movable counter-
    weight for fine adjustment. The sensor or the extension
    assembly is fastened to the pendulum rod by two pipe
    clamps.
    Boom Length 2.01 ft. (620 mm), stainless steel 1.4301
    Pendulum rod Length 6.39 ft. (1970 mm),
    stainless steel 1.4301
    Pendulum head, clamp POM/Polyethylene
    EH/W 170  Order No.: 109 274
    The EH/W 170 mounting assembly is designed for direct
    fastening to a wall of a basin. It can be set for pendulous or
    rigid operation, and it is suitable for extension assemblies.
    The immersion depth is adjusted by means of a fixing ring.
    Includes mounting plate with appropriate wall anchors and
    screws.
    Boom Length 0.84 ft. (260 mm), stainless steel 1.4301
    Pendulum head POM
    Mounting plate Diecast aluminum
    S 200  Order No.: 108 540
    The float with pendulum mounting assembly is available
    for use in flowing water or where the water level fluctuates
    con si der ably. The fixture is designed for extension assembly
    UA 55.
    A GWA weight ring is also required.
    Dimensions 2.76 x 1.07 ft. (850 x 330 mm) (L x W)
    Material PVC
    VIS Set-F  Order No.: 481 080
    Supplemental kit for horizontal mounting of a UV(-VIS)-
    sensor (NitraVis ? , CarboVis ? , NiCaVis ? ). Particularly suitable
    for heavily fluctuating water levels in combination with the
    S 200 electrode float.
    Material PVC/POM
    Vario Mounting Stand
    BE/ST 170  Order No.: 109 280
    Robust floor mounted stand made of stainless steel, with
    joint-locking fixture to accommodate a swing or pendulum
    mounting assembly and 2 pipe brackets for attaching a sun
    shield. With diecast aluminum baseplate, wall plugs and
    screws.
    Stand Length 5.51 ft. (1700 mm),
    diameter 1.97 in. (50 mm)
    Material Stainless steel 1.4301
    Brackets Polypropylene
    BE/ST 170-M  Order No.: 109 283
    Mounting stand similar to model BE/ST 170, but shorter
    version for wall mounting. Wall mounting material is
    included instead of the baseplate.
    Stand Length 3.15 ft. (970 mm),
    diameter 1.97 in. (50 mm)
    Material Stainless steel 1.4301
    BE/ST 170-R  Order No.: 109 281
    This stand is similar to model BE/ST 170, but with hardware
    for fastening of the stand to a vertical or horizontal pipe rail.
    Stand Length 3.15 ft. (970 mm), diameter 1.97 in. (50 mm)
    Material Stainless steel 1.4301
    128
    For information visit www.WTW.com for a customer care center near you
    Accessories Samplers Sample
    Preparation
    Analyzer Monitors IQ S enSor n et General Descrtption
    of Meters
    Mounting Hardware
    Fixtures Sun Shields
    BE/R 170  Order No.: 109 278
    With the BE/R 170 clamp set, a swing or pendulum
    mounting assembly can be fixed directly to a pipe; e.g. a
    handrail.
    Material Stainless steel 1.4301/diecast Al/POM
    BE/R 170-D  Order No.: 109 279
    The swivel/pivot clamp fixture provides secure connection
    of a swing or pendu lum mounting assembly to a horizontal
    pipe rail.
    Material Stainless steel 1.4301/diecast aluminum
    MR/SD 170  Order No.: 109 286
    Mounting kit for sun shields, suitable for horizontal or verti-
    cal pipe rails with diameters of 0.98 to 2.36 in.
    (25 - 60 mm). Sun shield not included.
    Material Stainless steel 1.4301
    BE/M 170  Order No.: 109 276
    With the BE/M 170, a swing or pendu lum mounting
    assembly can be inexpen sively installed directly at the basin
    edge or on top of a wall. It consists of a flange clamp with
    a clamping lever and a bolt-on base plate.
    Material Stainless steel 1.4301/diecast Al/POM
    BE/M 170 D  Order No.: 109 275
    Wall mounting similar model BE/M 170, but pivoting
    version.
    Material Stainless steel 1.4301/diecast Al
    SD/M 170-D  Order No.: 109 287
    Stainless steel double sun shield for parallel mounting of
    2 series 171, 170 measuring transducers and IQ S enSor n et .
    Dimensions 10.55 x 21.42 x 5.91 in.
    (268 x 544 x 150 mm) (H x W x D)
    Material Stainless steel, 1.4301
    SD/K 170  Order No.: 109 284
    Sun shield for mounting a junction box or an IQ S enSor n et
    module in the open air. Mounting kit MR/SD 170 is
    additionally required for attachment to vertical or horizontal
    pipes.
    Dimensions 5.59 x 9.06 x 3.43 in.
    (142 x 230 x 87 mm) (H x W x D)
    Material Stainless steel, 1.4301
    SSH/IQ  Order No.: 109 295
    Sunshield for mounting series 171, 170 and IQ S enSor n et
    monitors on a Vario Mounting Stand.
    Dimensions 13.03 x 13.54 x 9.45 in.
    (331 x 344 x 240 mm) (H x W x D)
    Material ASA (Dust gray color)
    VIS Set/EH IQ S enSor n et under sun shield SSH/IQ
    129
    For information visit www.WTW.com for a customer care center near you
    Flow-thru Adapters
    Flow-thru Vessels
    D 700/N
    Flow-thru vessel
    Order No. 203 745
    D 702/N
    Flow-thru vessel
    Order No. 203 747
    DMS/N
    Flow-thru vessel
    Order No. 203 749
    EBS 700-DU/N
    Flow-thru adapter
    Order No. 203 751
    EBST 700-DU/N
    Flow-thru adapter
    Order No. 203 753
    EBST 700-DU/ND
    Flow-thru adapter
    Order No. 203 754
    ESS 700 VA/N
    Welding socket
    Order No. 203 755
    ESS 700 VA/10 *
    Welding socket
    Order No. 203 757
    WA 700/2
    Retractable
    armature
    Order No. 480 102
    WA 700/10 *
    Retractable
    armature
    Order No. 480 100
    Sensor to be built in
    TriOxmatic ?
    690/700/
    700 IN/701/
    702 **
    ADA-DF3
    203 765
    ADA-DF4
    203 767
    and
    ADA-DF5
    203 769
    ADA-DF3
    203 765
    ADA-DF8
    203 775
    ADA-DF8
    203 775
    ADA-DF8
    203 775
    ADA-DF12
    203 783
    ESS-WA
    700/X
    480 10X
    ADA-WA2
    480 110
    ESS-WA
    700/X
    480 10X
    ADA-WA2
    480 110
    TetraCon ?
    700
    ADA-DF3
    203 765
    ADA-DF3
    203 765
    ADA-DF8
    203 775
    ADA-DF8
    203 775
    ADA-DF8
    203 775
    ADA-DF12
    203 783
    ESS-WA
    700/X
    480 10X
    ADA-WA2
    480 110
    ESS-WA
    700/X
    480 10X
    ADA-WA2
    480 110
    SensoLyt ?
    650/690/700
    ADA-DF2
    203 763
    ADA-DF10
    203 779
    ADA-DF10
    203 779
    ADA-DF10
    203 779
    ADA-DF10
    203 779
    ADA-DF13*
    203 785
    ESS-WA
    700/X
    480 10X
    ADA-WA3
    480 112
    ESS-WA
    700/X
    480 10X
    ADA-WA3*
    480 112
    VisoTurb ?
    700 IQ
    ADA-DF7
    203 773
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF11
    203 781
    ESS-WA
    700/X
    480 10X
    ADA-WA1
    480 108
    ESS-WA
    700/X
    480 10X
    ADA-WA1
    480 108
    ViSolid ?
    700 IQ
    ADA-DF7
    203 773
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF11
    203 781
    ESS-WA
    700/X
    480 10X
    ADA-WA1
    480 108
    ESS-WA
    700/X
    480 10X
    ADA-WA1
    480 108
    TetraCon ?
    700 IQ
    ADA-DF1
    203 761
    ADA-DF1
    203 761
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF11
    203 781
    ESS-WA
    700/X
    480 10X
    ADA-WA1
    480 108
    ESS-WA
    700/X
    480 10X
    ADA-WA1
    480 108
    SensoLyt ?
    700 IQ
    ADA-DF1
    203 761
    ADA-DF1
    203 761
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF11*
    203 781
    ESS-WA
    700/X
    480 10X
    ADA-WA1
    480 108
    ESS-WA
    700/X
    480 10X
    ADA-WA1*
    480 108
    TriOxmatic ?
    700 IQ/
    701 IQ
    ADA-DF1
    203 761
    ADA-DF4
    203 767
    and
    ADA-DF6
    203 771
    ADA-DF1
    203 761
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF11
    203 781
    ESS-WA
    700/X
    480 10X
    ADA-WA1
    480 108
    ESS-WA
    700/X
    480 10X
    ADA-WA1
    480 108
    TriOxmatic ?
    702 IQ
    ADA-DF4
    203 767
    and
    ADA-DF6
    203 771
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF11
    203 781
    ESS-WA
    700/X
    480 10X
    ADA-WA1
    480 108
    ESS-WA
    700/X
    480 10X
    ADA-WA1
    480 108
    FDO ?
    700 IQ
    ADA-DF14
    203 787
    ADA-DF1
    203 761
    ADA-DF15
    203 789
    ADA-DF15
    203 789
    ADA-DF15
    203 789
    ADA-DF11
    203 781
    ESS-WA
    700/X
    480 10X
    ADA-WA4
    480 114
    ESS-WA
    700/X
    480 10X
    ADA-WA4
    480 114
    AmmoLyt ? Plus
    700 IQ
    NitraLyt ? Plus
    700 IQ
    VARiON ? Plus
    700 IQ
    ADA-DF1
    203 761
    ADA-DF1
    203 761
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DF9
    203 777
    ADA-DFX Configuration recommended
    Configuration possible (check sensor specs and application) * with electrode SensoLyt ? SEA-HP
    Configuration not intended ** only for flow-thru vessel D 702/N
    130
    66.4 mm
    ?64 mm
    D 702/N
    VIS FT-1
    For information visit www.WTW.com for a customer care center near you
    Accessories Samplers Sample
    Preparation
    Analyzer Monitors IQ S enSor n et General Descrtption
    of Meters
    Flow-thru Adapters & Vessels
    Flow-thru adapters and
    flow-thru vessels
    WTW accessories can also be used for the IQ S enSor n et series. By the selec-
    tion of a suitable adapter all the previous and new WTW sensors of the 690
    and 70X (IQ) series can be mounted in the existing flow-thru adapters and
    vessels.
    Flow-thru Vessels
    Oxygen Flow-Thru Measurement
    D 702/N Order No.: 203 747
    In principle the flow-thru vessel D 702/N for continuous oxygen measure-
    ment can be fitted with all TriOxmatic ? sensors of the 690/70X (IQ) series.
    However, it is primarily intended for oxygen measurements in the ppb range
    (TriOxmatic ? 702 IQ), e.g. boiler feed water. In this application the flow-thru
    vessel is usually installed in the bypass of a water circula tion system. Please
    select an adapter from the table (see page 130/131).
    UV-VIS sensors in flow-thru measurement
    VIS FT-1 Order No.: 480 080
    Flow-thru cell for UV/VIS sensors NitraVis ? /CarboVis ? and NiCaVis ? 700 IQ
    (TS).
    The sensor can be cleaned automatically in mounted state by means of com-
    pressed air.
    Technical details and further flow-thru vessels see brochure
    “Product Details”.
    Flow-thru Adapters SW
    Flow-thru Vessels
    EBST/SW
    Flow-thru adapter
    Order No. 203 758
    EBST-D/SW
    Flow-thru adapter
    Order No. 203 759
    Sensor to be built in
    VisoTurb ? 700
    IQ SW
    ADA-DF9/
    SW
    203 790
    ADA-DF9/
    SW
    203 790
    ViSolid ? 700 IQ
    SW
    ADA-DF9/
    SW
    203 790
    ADA-DF9/
    SW
    203 790
    TetraCon ? 700
    IQ SW
    ADA-DF9/
    SW
    203 790
    SensoLyt ? 700
    IQ SW
    ADA-DF9/
    SW
    203 790
    TriOxmatic ?
    700 IQ SW
    ADA-DF9/
    SW
    203 790
    FDO ? 700 IQ
    SW
    ADA-DF9/
    SW
    203 790
    ADA-DFX
    Configuration
    recommended
    Configuration possible
    (check sensor specs and
    application)
    Configuration not
    intended
    131
    For information visit www.WTW.com for a customer care center near you
    only
    EBST 700 DU/ND
    Recommended direction of flow:
    TriOxmatic ? , FDO ? ,
    SensoLyt ? , TetraCon ? ,
    AmmoLyt ? , NitraLyt ? , VARiON ?
    VisoTurb ?
    ViSolid ?
    Flow-thru adapters
    EBST 700-DU/N and Order No.: 203 753
    EBST 700-DU/ND Order No.: 203 754
    Flow-thru adapter for measurements in pipelines, consisting
    of a 45° PVC T-piece (d 63 DN 50) with bonded sleeve,
    O-ring seals and union nut. The adapter must be com-
    pleted by the selection of a suit able sensor flange from the
    table on page 114 and can then be used for measurement
    of pH, oxygen, tem pera ture and conductivity with all cur-
    rent WTW sensors.
    EBST 700-DU/ND additionally features a compressed-air
    connection for cleaning installed sensors. Selection of
    sensors acc. table on page 130/131.
    Max. pressure 3 bar (EBST 700-DU/N)
    or resp. 0.2 bar (EBST 700-DU/ND)
    Max. temperature 122 °F (50 °C)
    Material PVC/POM
    EBS 700-DU/N  Order No.: 203 751
    Mounting set for flow-thru measure ments, consisting of a
    bonded sleeve for standard 45° PVC T-pieces (d 63 DN 50)
    or other suitable pipeline systems, one R 2” union nut and
    the necessary O-ring seals. Please select an adapter from
    the table on page 130/131.
    Max. pressure 3 bar
    Max. temperature 122 °F (50 °C)
    Material PVC/POM
    ESS 700 VA/N Order No.: 203 755
    Stainless steel weld-in socket, for measurements in pipelines.
    Please select an adapter from the table on page 130/131.
    Max. pressure 3 bar
    Max. temperature 122 °F (50 °C)
    Material
    Weld-in socket
    Union nut
    V4A stainless steel 1.4571
    PVC/-U
    Total length 5.59 in. (142 mm)
    Outside diameter 2.36 in. (60 mm)
    ESS 700 VA/10 Order No.: 203 757
    Stainless steel weld-in socket, for measurements in pipelines.
    Please select an adapter from the table on page 130/131.
    Max. pressure 10 bar
    Max. temperature 140 °F (60 °C)
    Material
    Weld-in socket
    Union nut
    V4A stainless steel 1.4571
    V4A stainless steel 1.4571
    Total length 5.59 in. (142 mm)
    Outside diameter 2.36 in. (60 mm)
    EBST 700-DU/N ESS 700 VA/10
    Flow-thru adapters for all sensors in the seawater version of
    Series 700 IQ SW / 701 SW IQ, see brochure “Product Details”.
    132
    For information visit www.WTW.com for a customer care center near you
    Accessories Samplers Sample
    Preparation
    Analyzer Monitors IQ S enSor n et General Descrtption
    of Meters
    Flow-thru Adapters & Vessels
    Apart from the two retractable armatures (for various pres-
    sure ranges) there are two different welding sockets (steel
    or stainless steel) and different matching adapters for
    mounting of the various online sensors with a shaft diame-
    ter of 1.57 in. (40 mm) available.
    Online measurements, of suspendend solids in particular,
    are increasingly performed directly in pipework or pressur-
    ized containers. Retractable armatures are used in order to
    enable assembly and removal of sensors during ongoing
    operation without interrupting the process. Depending on
    working pressure, these require suitable assembly aids in
    order to re-insert the sensor against the working pressure.
    Sensor adapter ADA-WA X
    Sensor for assembly
    with sensor connection cable
    Retractable armature WA 700
    with:
    Sensor sleeve with seal and
    supporting ring
    Welding socket ESS-WA 700 /X
    Retractable Armatures
    ? For pressurized applications
    up to 10 bar (overpressure)
    ? Insertion and removal of sensor
    during ongoing operation
    ? With compressed-air cleaning
    (optional)
    The universally applicable structure is as follows:
    Ordering Information
    Sensor adapter Order No.
    ADA-WA 1 Adapter for mounting of IQ sensors 480 108
    ADA-WA 2 Adapter for mounting of TriOxmatic ? 690/70X, CellOx ? 700 and TetraCon ? 700 480 110
    ADA-WA 3 Adapter for mounting of pH/ORP sensor assembly SensoLyt ? 690/700 480 112
    Retractable Armatures Order No.
    WA 700/10 Retractable armature for measurements in pipework, up to 10 bar (overpressure) 480 100
    WA 700/2 Retractable armature for measurements in pipework, up to 2 bar (overpressure) 480 102
    Welding socket Order No.
    ESS-WA 700/ST Steel welding socket (St 33) 480 104
    ESS-WA 700/VA Stainless steel welding socket (1.4571) 480 106
    Please refer to table on page 130/131
    133
    For information visit www.WTW.com for a customer care center near you
    Cleaning System
    Some applications, in particular in the wastewater treatment, require special precautions for permanent and interference-
    free operation.
    Efficient compressed air cleaning put into practice:
    Cleaning System
    ? Solutions for all plants
    ? Controllable via any WTW monitor
    ? Compressed air cleaning –
    winterized and interference-free
    For cleaning, compressed air is blown at the sensor element (from external source) freeing it from pollutants. The compressed
    air from the cleaning air box or installation to the sensor is switched on or off electronically by an activated control valve or
    relay. The control is regulated by a timer via the IQ S enSor n et or via a relay of the measuring system.
    Option 1:
    Compressed-air supply is provided at the plant.
    You require the following components
    ? Cleaning head CH
    ? Valve module (MIQ/CHV PLUS or DIQ/CHV with MIQ/PS)
    Option 2:
    Compressed-air supply is not provided at the plant.
    You require the following components
    ? Cleaning head CH
    ? Cleaning Air Box
    ? Monitor with relay output
    For a continuous compressed-air cleaning system there are
    two options:
    MIQ/CHV PLUS or DIQ/CHV
    Bus directly
    or:
    Relay of MIQ/CR3, DIQ/S 182
    or:
    Monitors 170/296 with R option
    CH
    Cleaning Air Box
    MC S
    ESC
    OK
    Sensor
    DIQ/S 182 resp. MIQ/CR3 or MIQ/R6
    with 1 free relay output
    or:
    170/296 monitor with 1 free relay output
    CH
    Cleaning head
    Air exit nozzles
    Sensor element
    Compressed air
    tubing
    Cleaning Air Box
    134
    Cleaning Air Box
    For information visit www.WTW.com for a customer care center near you
    Accessories Samplers Sample
    Preparation
    Analyzer Monitors IQ S enSor n et General Descrtption
    of Meters
    Cleaning System
    Ordering Information
    Order No.
    CH Cleaning head with tube (16.4 yds/ 15 m)  900 107
    MIQ/CHV PLUS Valve module for cleaning system (IQ S enSor n et , system 184 XT or 2020 XT) 480 018
    DIQ/CHV Valve module for cleaning system (IQ S enSor n et , system 182) 472 007
    MIQ/PS Wide-range power supply 480 004
    Order No.
    Cleaning Air Box Cleaning air box with compressor, 230 VAC with air-filter 480 019
    Cleaning Air Box Cleaning air box with compressor, 115 VAC with air-filter 480 017
    AF/Cleaning Air Box Air-filter for the suction side of the pump, annual exchange 408 026
    RM/Cleaning Air Box Spare membrane for the membrane pump of the cleaning box,
    exchange after 5000 operating hours or after 5 years
    480 027
    BPV Check-valve, which is installed in the box between pump and compressed-air hose.
    It stops the measuring solution from rising and entering the cleaning nozzles in the hose system and
    contaminating it. It can also be used for the EBST 700 DU/ND.
    480 029
    The cleaning air box is a air-pressure compressor supplying
    the cleaning air to the various sensors.
    Compared with the former systems with the cleaning head
    valve (CHV) the cleaning air box does not require any special
    valve installation as well as no compressed-air supply on site.
    The cleaning air box can be controlled by any WTW
    supplied converter via a relay (exception: MIQ/VIS).
    The great advantage of this cleaning air box compared to
    any former systems with CHV (cleaning had valve):
    No compressed-air system is required on site. The cleaning
    air box is delivered in two models 115 VAC (480 017) and
    230 VAC (480 019).
    Thanks to the installation of the membrane compressor and
    the pre-switched filters, the cleaning air box provided oil
    and dust-free compressed-air, which guarantees keeping
    the sensor clean.
    Cleaning Air Box
    ? Oil-free compressed-air
    ? Most easy installation
    ? Decentralized weatherproof
    compressed-air supply on site
    135
    For information visit www.WTW.com for a customer care center near you
    Inlet Outlet
    Pressure controller for
    pressure reduction
    Dosing valve to adjust the flow
    Measuring transmitter for
    flow measurement
    Chlorine
    measuring cell
    Turbidimeter
    Multi parameter transmitter
    PVC mounting plate,
    approx. 100 x 75 x 1.2 cm
    (H x W x D)
    pH electrode
    Cond. electrode
    ORP electrode
    Flow through armature
    Flow measuring cell
    Calibration
    console
    MULTILINE 1000
    ? Intuitive menu navigation
    ? Pre-mounted panels
    ? Excellent cost / performance ratio
    ? No chemicals
    The individual configurable
    multi-parameter system
    Example: Chlorine measurement Cl 7010
    Monitoring Systems for drinking water control
    As the only complete system, MULTILINE 1000 offers
    convenient measuring and output of up to six parameters
    with a single transmitter.
    Ready-to-operate monitoring system offers easy interface,
    including the touchscreen with intuitive menu navigation.
    Also single parameters
    The parameters pH, ORP, C ond , D.O. and chlorine are
    mounted on a panel and are supplied with a pressure
    reducer as well as a ball valve for flow-through-regulation.
    The flow-control switch can be integrated optionally, to
    give an alarm signal when flow is disrupted.
    Parameters
    pH / ORP pH 5000
    Conductivity LF 6000
    Chlorine (free and total) – electrochemical Cl 7010
    Chlorine (free and total) – photometric Chlorine 3000
    Turbidity Turb 2000 – Turb 2120
    Oxygen Oxi 4000
    136
    For information visit www.WTW.com for a customer care center near you
    Turb 2000 – Turb 2120
    Chlorine 3000
    ? Easy calibration
    ? Integrated bubble trap
    ? Proven system
    ? Low consumption of reagents
    ? 30 days maintenance-free operation
    ? Excellent cost/performance ratio
    Instruments for measuring turbidity
    for any application
    Analyzers for free and total chlorine
    The nephelometric turbidity measuring is offered with or
    without ultrasonic cleaning of the flow-through cuvette.
    Selection between measuring acc. DIN 7027 with infrared
    light and measuring acc. US EPA 180.1 with white light.
    The instruments not only offer excellent handling, but also
    technical specifications:
    ? Measurement range 0 ... 1000 NTU,
    accuracy 0.0001 NTU
    ? RS 485 MODBUS or 4 – 20 mA output adjustable
    ? Two programmable alarm outputs 250 VAC/2A
    The analyzer operates photometric with the DPD method
    acc. US EPA.
    The measuring range from 0 – 10 mg/l is extremely wide
    with an accuracy of 0.01 mg/l. The instrument features
    2 alarm outputs, one 4 – 20 mA output as well as one
    RS 485 MODBUS output.
    137
    O 2
    pH
    Cond
    O 2
    pH
    Cond
    O 2
    pH
    Cond
    pH
    Cond
    photoLab ? 6100 VIS / 6600 UV-VIS
    photoLab ? S6 / S12
    pHotoFlex ?  Series
    ? Photometrical Tests
    wide range of tests available
    Multi-parameter:
    Multi 9310 IDS,
    Multi 9420 IDS,
    Multi 9430 IDS
    Single Parameter:
    7110, 7310, 7320
    ? pH
    ? ISE
    ? D.O.
    ? Cond
    ? Multi
    Turb ? 430 / 355 / 550 / 555
    ? NTU
    ProfiLine 1970i
    ? pH
    ? D.O.
    ? Cond
    ? Multi
    OxiTop ? / OxiTop ? Control
    ? BOD
    ? Respiration
    soil respiration,
    biodegradation
    OECD, Biogas
    determination,
    respiration rate
    Multi-parameter:
    MultiLine ? 3000 Series /
    Multi 340i /  350i /
    3400i* /  3500i*
    Single Parameter:
    ProfiLine 3000 Series
    ? pH
    ? ISE
    ? D.O.
    ? Cond
    ? Multi
    * North
    American
    version
    WTW – Laboratory and Field Instrumentation
    Please order the new
    WTW Catalog “Laboratory
    and Field Instrumentation”
    Are you interested?
    Photometers Laboratory Meters inoLab ?
    Turbidity Meters
    Field Meters
    Respirometer OxiTop ?
    Portable Meters
    MPP 910 / 930 IDS
    ? pH
    ? D.O.
    ? Cond
    ? Multi
    ? Depth profiles
    Multi-parameter probe
    138
    Biodegradation
    according to OECD
    OECD 301: Determination
    with OxiTop ? Control
    Typical Applications
    Environmental
    Monitoring
    e.g.
    Photometric Measurements
    with pHotoFlex ?
    Pharmaceutical Water
    e.g.
    Conductivity Flow
    Measurement
    with
    inoLab ? Cond 7310
    Chemical Water
    e.g.
    pH/Conductivity
    Measurement
    with
    inoLab ? Multi 9420 IDS
    Ground Water
    e.g.
    D.O./pH/Conductivity
    Measurement
    with Multi 350i/3500i*
    and MPP 350
    Surface Water
    e.g.
    D.O./pH/Conductivity
    Measurement with
    MultiLine ? 3430
    + FDO ? 925
    Depths Profiles,
    Limnology
    e.g.
    D.O./pH/ Conductivity
    Profiles with MultiLine ? 3430
    + MPP 930 IDS
    Biotechnology
    (not autoclavable)
    e.g.
    D.O./pH/Conductivity
    Measurement
    with MultiLine ? 3410 + FDO ? 925
    BOD Measurement
    e.g. Dilution BOD with Analysis Pro-
    gram: inoLab ? BSB/BOD 740; easy
    Self-Check Measurement
    with OxiTop ?
    Fish Farming
    e.g.
    D.O. Measurement
    with ProfiLine Oxi 3205
    and DurOx ?

     


    在线询盘/留言 请仔细填写准确及时的联系到你!
    您的姓名: * 预计需求数量: *    
    联系手机: * 移动电话或传真:
    电子邮件: * 所在单位:
    咨询内容:
    *
     
    更多..本企业其它产品

    机电之家网 - 机电行业权威网络宣传媒体

    关于我们 | 联系我们 | 广告合作 | 付款方式 | 使用帮助 | 会员助手 | 免费链接

    Copyright 2011 jdzj.com All Rights Reserved技术支持:杭州滨兴科技股份有限公司

    客户服务热线:0571-87774297
    网站经营许可证:浙B2-20080178 浙B2-20080178-4


    经营性网站备案信息 ICP经营
    许可证
    营业执照(副本) 不良信息举报中心